AH Motion Controller – Motion Control Instructions Manual MC_GearIn _3 - The gear ratio is defined by the values specified in RatioNumerator (numerator) and RatioDenominator ( denominator ) . - A negative gear ratio indicates that the directions for the master and slave axis are opposite. - You can define the reference source for master axis as commanded value or actual value. - Acceleration , Deceleration and Jerk allows you to specify a desired behavior for the slave axis to engage with the master axis when the instruction is executed. Inputs 3-182 FB/FC Description FB MC GearIn establishes the gear relation (velocity) between master and slave axis.
_ Name Function Data type Setting value (Default value) Timing for updating Execute Executes the instruction when Execute changes to True. BOOL True/False (False) - Continuous Update Continuously updates the gear ratio between the master and slave axes when Continuousupdate is True. BOOL True/False (False) When Active shifts to True and it will update continuously. RatioNumerator The numerator of the electronic gear ratio between the master and slave axes. A negative gear ratio indicates the directions DINT Negative number, positive number or 0 (0) When Execute shifts to True and Busy is False.