Chapter 3 Motion Control Instructions 3_ *Note: 1. Refer to Section 2.4 Data Type Unit (DUT): ENUM for explanation on using enumerations. Outputs 3-183 Name Function Data type Setting value (Default value) Timing for updating for the master and slave axis are opposite. RatioDenominator The denominator of the electronic gear ratio between the master and slave axes. A negative gear ratio indicates the directions for the master and slave axis are opposite. DWORD Positive number (0) When Execute shifts to True and Busy is False. MasterValueSource Specifies the reference position of the master axis. eMC SOURCE*1 _ 0: mcCommandedValue 2:
mcActualValue (0) When Execute shifts to True and Busy is False. Acceleration Acceleration rate. (Unit: user unit/s2) * LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. Deceleration Deceleration rate. (Unit: user unit/s2) * LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. Jerk Jerk value. (Unit: user unit/s3) * LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. BufferMode Specifies the buffering behavior of the instruction. eMC BUFFER M _ _ ODE*1 0: mcAborting 1: mcBuffered (0) When Execute shifts to True and Busy is False.
Name Function Data type Output range (Default value) InGear True when the gear operation is completed and the in-gear status is acknowledged. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Active True when the axis is being controlled. BOOL True/False (False) CommandAborted True when the instruction is aborted. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False)