AH Motion Controller – Motion Control Instructions Manual *Note: Refer to Section 2.4 Data Type Unit (DUT): ENUM for explanation on using enumerations . Outputs _3 Outputs Update Timing 3-194 Name Function Data type Output range (Default value) Done True when phasing operation is completed. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Active True when the axis is being controlled. BOOL True/False (False) CommandAborted True when the instruction is aborted. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code when the error occurs. Refer to Appendices for error code descriptions.
DWORD 16#0~16#FFFFFFFF (0) AbsolutePhaseShift Records the absolute phase shift on the master axis continuously. LREAL - Name Timing for shifting to True Timing for shifting to False Done When the phasing operation is completed. When Execute shifts from True to False. If Execute is False and Done shifts to True, it will be True for only one period and immediately shift to False. Busy When Execute changes to True. When Done shifts to True. When Error shifts to True. When CommandAborted shifts to True. Active When the motion on the axis is started. When Execute shifts to False. When Error shifts to True. When CommandAborted shifts to True.
If Execute is False and CommandAborted shifts to True, it will be True for only one period and immediately shift to False. CommandAborted When this instruction is aborted by another instruction with the Buffer Mode set to Aborting. When this instruction is aborted because of the execution of MC Stop _ instruction. When Execute changes to False. If Execute is False and CommandAborted shifts to True, it will be True for only one period and immediately shift to False.