Delta Electronics AH — MC_PhasingAbsolute

Chapter 3 Motion Control Instructions  Timing Diagram Execute Done Busy Active 3_ CommandAborted Error Error ID  In-Outs *Note : Kn refers to the maximum supported axes of different models. For example, AH20EMC-5A supports K1~K32.  Function - MC_PhasingAbsolute shifts the phase of the master axis virtually by a specified absolute phase shift value. - The instruction only affects the velocity and position of the slave axis without any influence on the velocity and position of the master axis. - When MC_PhasingAbsolute instruction is executed but not finished yet, it will not take effects to execute the instruction again.

- The reference zero point for calculating the PhaseShift value is the position when the synchronization between master and slave axis starts. - For detailed explanation of the absolute phasing operation, refer to Programming Example below.  BufferMode BufferMode determines the behavior to combine the axis motions for this instruction and the previous instruction. When the instruction is executed; 3-195 Name Timing for shifting to True Timing for shifting to False Error/ErrorID  When an error occurs in the execution conditions or input values for the instruction.(Error code is recorded)  When Execute shifts from True to False.

 (Error code is cleared) AbsolutePhaseShift Continuously updates value when Busy is True. Continuously updates value when Busy is True. Name Function Data type Setting value Timing for updating (Default value) Master Master Axis WORD K1~Kn* (0) When Execute is rising edge triggered and Busy is False. Slave Slave Axis WORD K1~Kn* (0) When Execute is rising edge triggered and Busy is False.