AH Motion Controller – Motion Control Instructions Manual MC_PhasingRelative _3 1. The gear relation between the specified master and slave axes, e.g. electronic gear relationship, electronic cam relationship, should be established before the execution of MC_PhasingAboslute/MC_PhasingRelative. 2. The virtually shifted master axis will impact the motion of the slave axis according to the specified parameters. Inputs 3-200 FB/FC Description FB MC PhasingRelative shifts the phase of the master axis virtually by a specified relative phase shift value. _ Name Function Data type Setting value (Default value) Timing for updating Execute Executes the instruction when Execute changes to True.
BOOL True/False (False) - PhaseShift Specifies the relative phase shift amount for master axis. (Unit: user unit)* LREAL Negative number, positive number or 0 (0) When Execute shifts to True and Busy is False. Velocity The target velocity of the master axis phase shift amount. (Unit: user unit/s)* LREAL Positive number (0) When Execute shifts to True and Busy is False. Acceleration Acceleration rate. (Unit: user unit/s2)* LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. Deceleration Deceleration rate. (Unit: user unit/s2)* LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. Jerk Jerk value. (Unit:
user unit/s3)* LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. BufferMode Specifies the buffering behavior of the instruction. eMC BUFFER _ _ MODE*2 0: mcAborting 1: mcBuffered (0) When Execute shifts to True and Busy is False.