Delta Electronics AH — MC_PhasingRelative

Chapter 3 Motion Control Instructions *Note: 1. Refer to Section 2.4 Data Type Unit (DUT): ENUM for explanation on using enumerations .  Outputs 3_  Outputs Update Timing 3-201 Name Function Data type Output range (Default value) Done True when phasing operation is completed. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Active True when the axis is being controlled. BOOL True/False (False) CommandAborted True when the instruction is aborted. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code when the error occurs. Refer to Appendices for error code descriptions.

DWORD 16#0~16#FFFFFFFF (0) CoveredPhaseShift Records the absolute phase shift on the master axis continuously LREAL - Name Timing for shifting to True Timing for shifting to False Done  When the phasing operation is completed.  When Execute shifts from True to False.  If Execute is False and Done shifts to True, it will be True for only one period and immediately shift to False. Busy  When Execute changes to True.  When Done shifts to True.  When Error shifts to True.  When CommandAborted shifts to True. Active  When the motion on the axis is started.  When Execute shifts to False.  When Error shifts to True.  When CommandAborted shifts to True.

 If Execute is False and CommandAborted shifts to True, it will be True for only one period and immediately shift to False. CommandAborted  When this instruction is aborted by another instruction with the Buffer Mode set to Aborting.  When this instruction is aborted because of the execution of MC Stop _ instruction.  When Execute changes to False.  If Execute is False and CommandAborted shifts to True, it will be True for only one period and immediately shift to False.