Delta Electronics AH — DFB_AxisSetting1

AH Motion Controller – Motion Control Instructions Manual DFB_AxisSetting1 _3 The function blocks Vbias, Tacc and Tdec are for the axis velocity settings in the DFB series function blocks. This instruction can only be executed when the state is in Disable, Standstill or Coordinated and the axis should be in Standby mode. Otherwise, an error message will be sent. Note: refer to DFB_AxisSetting2 for setting other motion axis parameters.  Inputs  Outputs 3-210 FB/FC Description FB DFB AxisSetting1 sets motion parameters for the specified axis. _ Name Function Data type Setting value (Default value) Timing for updating Execute Writes in the parameters when Execute changes to True.

BOOL True/False (False) - Vmax Maximum speed (user unit: s) LREAL 0~2147483647.0 (0) When Execute shifts to True and Busy is False. Vbias Start-up speed (user unit: s) LREAL 0~100000.0 (0) When Execute shifts to True and Busy is False. Tacc Acceleration time (unit: ms) WORD 0~32767 (0) When Execute shifts to True and Busy is False. Tdec Deceleration time (unit: ms) WORD 0~32767 (0) When Execute shifts to True and Busy is False. Name Function Data type Output range (Default value) Done True when the parameter setting is completed. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Error True if an error occurs.

BOOL True/False (False) ErrorID Indicates the error code if an error occurs. DWORD 16#0~16#FFFFFFFF (0)