Chapter 3 Motion Control Instructions Outputs Update Timing 3_ Timing Diagram Execute Done Busy Error Error ID In-Outs *Note : Kn refers to the maximum supported axes of different models. For example, AH20EMC-5A supports K1~K32. Function DFB_AxisSetting1 sets motion parameters for the specified axis. You can set the motion parameters including maximum speed of the axis ( Vmax ), the start-up speed ( Vbias ), the time it takes for the start-up speed to increase to its running speed ( T acc ), and the time it takes for the running speed to decrease to its start-up speed ( Tdec ). The motion diagram explaining the above parameters is as below.
3-211 Refer to Appendices for error code descriptions. Name Timing for shifting to True Timing for shifting to False Done When the specified target distance is completed When Execute shifts from True to False. If Execute is False and Done shifts to True, it will be True for only one period and immediately shift to False. Busy When Execute changes to True. When Done shifts to True. When Error shifts to True. Error/ErrorID When an error occurs in the execution conditions or input values for the instruction.(Error code is recorded) When Execute shifts from True to False.
(Error code is cleared) Name Function Data type Setting value Timing for updating (Default value) Axis Motion axis number WORD K1~Kn* (0) When Execute is rising-edge triggered and Busy is False.