Delta Electronics AH — DFB_AxisSetting2

Chapter 3 Motion Control Instructions DFB_AxisSetting2 - DFB _AxisSetting2 sets motion parameters for the specified axis. You can set the motion parameters including velocity curve ( Vcurve ), the pulse output type ( OutputType ), and the user unit system ( Unit ). For example, the setting 3_ of pulse number for a motor to rotate once ( PulseRev ) and the moving distance when the motor rotates once ( DistanceRev ) should be specified if mechanical unit system is required. - This instruction can only be executed when the state is in Disable, Standstill or Coordinated and the axis should be in Standby mode. Otherwise, an error message will be sent. Note:

refer to DFB_AxisSetting1 for setting other motion axis parameters.  Inputs  Outputs 3-213 FB/FC Description FB DFB AxisSetting2 sets motion parameters for the specified axis. _ Name Function Data type Setting value (Default value) Timing for updating Execute Writes in the parameters when Execute changes to True. BOOL True/False - (False) Vcurve Velocity curve BOOL Trapezoid: False S Curve: True (False) When Execute shifts to True and Busy is False. PulseRev Number of pulses per motor revolution DWORD 1〜99999999 (0) When Execute shifts to True and Busy is False. DistanceRev Travel distance per motor revolution LREAL 1~1000000.0 (0) When Execute shifts to True and Busy is False.

Name Function Data type Output range (Default value) Done True when the parameter setting is completed. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False)