Delta Electronics AH — DFB_AxisSetting2

AH Motion Controller – Motion Control Instructions Manual  Outputs Update Timing _3  Timing Diagram Execute Done Busy Error Error ID  In-Outs *Note : Kn refers to the maximum supported axes of different models. For example, AH20EMC-5A supports K1~K32.  Troubleshooting - If an error occurs during the execution of the instruction or when the axis is in the state of “Errorstop”, Error will change to True and the axis will stop moving. You can refer to ErrorID (Error Code) to address the problem. - Information regarding error codes and indicators and the associated troubleshooting information are attached as Appendices for a quick reference.

For the complete troubleshooting of the system, refer to AH Motion Controller – Operation Manual . 3-214 Name Function Data type Output range (Default value) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions. DWORD 16#0~16#FFFFFFFF (0) Name Timing for shifting to True Timing for shifting to False Done  When the specified target distance is completed  When Execute shifts from True to False.  If Execute is False and Done shifts to True, it will be True for only one period and immediately shift to False. Busy  When Execute changes to True.  When Done shifts to True.  When Error shifts to True.

Error/ErrorID  When an error occurs in the execution conditions or input values for the instruction.(Error code is recorded)  When Execute shifts from True to False. (Error code is cleared) Name Function Data type Setting value Timing for updating (Default value) Axis Motion axis number WORD K1~Kn* (0) When Execute is rising-edge triggered and Busy is False.