Delta Electronics AH — DFB_InputPolarity

Chapter 3 Motion Control Instructions  Timing Diagram Enable Busy Valid 3_  Supported Products - AH Motion Controller CPU: AHxxEMC-5A - AH series motion control modules: AHxxEMC-5A 3-221 signal is OFF during operation.  When the output is OFF and the external signal is ON during operation.  When the output is ON and the external signal is ON during operation.  When the output is OFF and the external signal is OFF during operation. Nor X1 05 _ _  When the output is ON and the external signal is OFF during operation.  When the output is OFF and the external signal is ON during operation.  When Enable shifts to False.

 When the output is ON and the external signal is ON during operation.  When the output is OFF and the external signal is OFF during operation.