Delta Electronics AH — DFB_CamMultiRead

AH Motion Controller – Motion Control Instructions Manual DFB_CamMultiRead - The CamTableId decides the motion axis of the cam curve where the cam point will be read. ReadStartPointNo defines the starting number of the cam point. ReadAmount defines the total amount of CAM data to be read from the _3 value specified in ReadStartPointNo (the starting number of the cam point). MasterPosition and SlavePosition define the master and slave positions (coordinates of the cam point) read from the motion axis. *Note: 1. CAM table ID is the number corresponding to the ID Number of the created E-CAM table in ISPSoft. 2.

Refer to the resolution of the E-CAM table in the ISPSoft for the range of the data points.  Inputs  Outputs 3-222 FB/FC Description FB DFB CamRead reads cam points from the specified motion axis. _ Name Function Data type Setting value (Default value) Timing for updating CamTableId CAM table ID*1 WORD K1~K32 (0) When Enable shifts to True. Enable Executes the instruction when Enable changes to True. The specified cam point will then be read from the cam curve. BOOL True/False (False) - ReadStartPoint The starting number of the cam DWORD 0~2047 When Enable shifts to True. No point to be read (0) it udates value continuously.

ReadAmount The total amount of CAM data to be read WORD 1~64 (0) When Enable shifts to True, it udates value continuously. Name Function Data type Output range (Default value) Valid True when the specified cam point is read from the cam curve. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions. DWORD 16#0~16#FFFFFFFF (0)