Delta Electronics AH — DFB_CamMultiRead

Chapter 3 Motion Control Instructions  Outputs Update Timing 3_  Timing Diagram Enable Valid Error Error ID  Troubleshooting - If an error occurs during the execution of the instruction or when the axis is in the state of “Errorstop”, Error will change to True and the axis will stop moving. You can refer to ErrorID (Error Code) to address the problem. - Information regarding error codes and indicators and the associated troubleshooting information are attached as Operation Manual . Appendices for a quick reference. For the complete troubleshooting of the system, refer to AH Motion Controller –  Programming Example Please refer to the programming example of DFB_CamWrite.

 Supported Products - AH Motion Controller CPU: AHxxEMC-5A - AH series motion control modules: AHxxEMC-5A 3-223 MasterPosition Master position which is read. LREAL Positive value (0) SlavePosition Slave position which is read. LREAL Positive or negative value (0) Name Timing for shifting to True Timing for shifting to False Valid  When the specified cam point is read from the cam curve.  When Enable shifts to False. Error(ErrorID)  When an error occurs in the execution conditions or input values for the instruction. (error code is recorded)  When Execute shifts from True to False. (error code is cleared) MasterPosition  Updates value continuously when the instruction is enabled.

 Updates value continuously when the instruction is enabled. SlavePosition  Updates value continuously when the instruction is enabled.  Updates value continuously when the instruction is enabled.