AH Motion Controller – Motion Control Instructions Manual DFB_CamMultiWrite - The CamTableId decides the motion axis of the cam curve which is to be written with the cam point. CamPointNo _3 defines the number of the cam point; MasterPosition and SlavePosition define the master and slave positions (coordinates of the cam point) which are to be written into the cam profile. Inputs *Note: 1. CAM table ID is the number corresponding to the ID Number of the created E-CAM table in ISPSoft. 2. Refer to the resolution of the E-CAM table in the ISPSoft for the range of the data points.
3-224 FB/FC Description FB DFB CamWrite writes cam points to the specified cam curve _ Name Function Data type Setting value (Default value) Timing for updating CamTableId CAM table ID*1 WORD K1~K32 (0) When Execute shifts to True and Busy is False Execute Executes the instruction when Execute changes to True. The specified cam point will then be written into the cam curve.
BOOL True/False (False) - WriteStartPointNo The starting number of the cam point to be writeen DWORD 0~2047 (0) When Execute shifts to True and Busy is False WriteAmount The total amount of CAM data to be written WORD 1~64 (0) When Execute shifts to True and Busy is False MasterPosition Master position which is to be written. Array [64] of LREAL Positive value (0) When Execute shifts to True and Busy is False SlavePosition Slave position which is to be written. Array [64] of LREAL Positive or negative value (0) When Execute shifts to True and Busy is False