Chapter 2 Devices, Symbols and Instructions 2_ 2-13 AXIS REF _ Description Factory setting Members Data type Function Setting range (Default) Max Accelerate _ time _ INT Maximum acceleration time (TACC); unit: ms 0~1,000 ms 500 Max Decelerat _ e time _ INT Maximum deceleration time (TDEC); unit:
ms 0~1,000 ms 500 Target cm _ d position _ 1 32 DINT Target position of the axis specified (User Unit) -(231)~(231-1) 0 Target cm _ d position _ f _ 64 LREAL (+-)1.7976931348 *(10308) Target cm _ d speed1 _ 32 DINT Speed at which the axis specified rotates (User Unit) 0~(231-1) 0 Target cm _ d speed f _ _ 64 LREAL 0~1.7976931348* (10308) Current c _ md positio _ n UU _ 32 DINT Present command position of the axis specified (User Unit) -(231)~(231-1) 0 Current c _ md positio _ n UU f _ _ 64 LREAL (+-) 1.7976931348* (10308) 0 Current a _ ctual spee _ d 32 DINT Present command speed of the axis specified (User Unit/S) 0~(231-1) PPS 0 Current a _ ctual spee _ d UUperS _ f _ 64 LREAL 0~1.7976931348* (10308) 0 Position Lim P _ _ ositive f _ LREAL Positive dirction position limit (User Unit) 0~1.7976931348* (10308) 2,147,483,647 Position Lim N _ _ egative f _ LREAL Negative dirction position limit (User Unit) 0~-1.7976931348* (10308) 2,147,483,647 Max Accelerati _ on f _ LREAL Maximum Acceleration (User Unit /S2) 0~1.7976931348* (10308) 1,000 Target cmd Ac _ _ celeration F _ LREAL Target acceleration of the axis specified (User Unit /S2) 0~1.7976931348* (10308) 1,000 Max Decelerati _ on f _ LREAL Maximum Dcceleration (User Unit /S2) 0~1.7976931348* (10308) 1,000 Target cmd De _ _ celeration f _ LREAL Target deceleration of the axis specified (User Unit /S2) 0~1.7976931348* (10308) 200,000