Delta Electronics AH — 2.2.1 Parameters for Motion Axes: Structure

AH Motion Controller – Motion Control Instructions Manual _2 * 1 : State of the designed axis 2-14 AXIS REF _ Description Members Factory setting Data type Function Setting range (Default) Target cmd Je _ _ rk f _ LREAL Target jerk of the axis specified (User Unit /S3) 0~1.7976931348* (10308) 0 Max position o _ _ f Rotary Axis f _ _ _ LREAL Maximum position of rotational axis (User Unit ) 0~2,147,483,647 2,147,483,647 Min position of _ _ Rotary Axis f _ _ _ LREAL Minimum position of rotational axis (User Unit ) -2,147,483,647~0 -2,147,483,647 Current Axis e _ _ rror code _ WORD Axis error code Please refer to the error code tables in appendix A.

0 Egear ratio Nu _ _ merator INT Electronic gear ratio of the axis specified (Numerator) 1~99,999,999 128 Egear ratio De _ _ nominator INT Electronic gear ratio of the axis specified (Denominator) 1~99,999,999 1 Electrical zero _ DINT Electrical zero of the axis specified Users can set the value according to their needs. 0 StateMachine _ AxisStatus*1 WORD State of the designed axis Refer to the table below 2 Axis number Description 2 Disabled 3 Standstill 4 Homing 5 Stopping 6 ContinuousMotion 7 SynchronizedMotion 8 DiscreteMotion 9 Coordinated 10 CoordinatedHalt 11 CoordinatedStop