Delta Electronics AH — DFB_GroupEnable

AH Motion Controller – Motion Control Instructions Manual  Outputs _3  Outputs Update Timing  Timing Diagram  Function  AxisNumOrder_1 ~ AxisNumOrder_6 indicate the 6 dimensions which are also the 6 axes of the coordinates: X, Y, Z, A, B, and C. You need to specify “0” to the axis number input which is not to be used.  The first axis, AxisNumOrder_1 , should always be given an axis number. 3-272 AxisNumOrder 6 _ Designates the axis number for the 6th axis (C-axis ) WORD 1~32 (0) When Execute shifts to True and Busy is False. Name Function Data type Output range (Default value) Done True when the parameter setting is completed.

BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions. DWORD 16#0~16#FFFFFFFF (0) Name Timing for shifting to True Timing for shifting to False Done  When the axis group is enabled  When Execute shifts from True to False.  If Execute is False and Done shifts to True, it will be True for only one period and immediately shift to False. Busy  When Execute changes to True.  When Done shifts to True.  When Error shifts to True.

Error(ErrorID)  When an error occurs in the execution conditions or input values for the instruction.(Error code is recorded)  When Execute shifts from True to False. (Error code is cleared)