AH Motion Controller – Motion Control Instructions Manual DFB_GroupReset - The axis group will be available for group motion in “Standby” state. - The state of the axis group will enter “Standby” after DFB_GroupReset is executed. Note: For more information about the state of axis as well as group and the timing to use DFB_GroupReset, refer to 7.4 _3 State Transitions of AH Motion Controller – Operation Manual .  Inputs  Outputs  Outputs Update Timing 3-276 FB/FC Description FB DFB GroupReset resets the axis group which is in the state of “Errorstop”. _ Name Function Data type Setting value (Default value) Timing for updating GroupNum Specifies the number of the axis group.

WORD 1~16 (0) When Execute shifts to True and Busy is False. Execute Executes the instruction when Execute changes to True. BOOL True/False (False) - Name Function Data type Output range (Default value) Done True when the axis group is reset. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions. DWORD 16#0~16#FFFFFFFF (0) Name Timing for shifting to True Timing for shifting to False Done  When the axis group is reset  When Execute shifts from True to False.

 If Execute is False and Done shifts to True, it will be True for only one period and immediately shift to False. Busy  When Execute changes to True.  When Done shifts to True.