Chapter 3 Motion Control Instructions  Timing Diagram 3_  Troubleshooting - If an error occurs during the execution of the instruction or when the axis is in the state of Errorstop, Error will change to True and the axis will stop moving. You can refer to ErrorID (Error Code) to address the problem. - Information regarding error codes and indicators and the associated troubleshooting information are attached as Operation Manual . Appendices for a quick reference. For the complete troubleshooting of the system, refer to AH Motion Controller –  Programming Example The example disables the axis group which is enabled by DFB_GroupEnable. 1.

Suppose that group number 1 is enabled by DFB_GroupEnable. DFB_GroupDisable can be used to disable group number 1, so as to perform single axis motion on the axes used in this axis group. 2. Set M110 to True the disable the axis group (1) which is designated by GroupNum . 3. When M111 changes to True, the disabling of group number 1 is completed.  Supported Products - AH Motion Controller CPU: AHxxEMC-5A - AH series motion control modules: AHxxEMC-5A 3-275 Name Timing for shifting to True Timing for shifting to False Busy  When Execute changes to True.  When Done shifts to True.  When Error shifts to True.

Error(ErrorID)  When an error occurs in the execution conditions or input values for the instruction.(Error code is recorded)  When Execute shifts from True to False. (Error code is cleared)