AH Motion Controller – Motion Control Instructions Manual DFB_GroupDisable - The axes in the disabled group will be available for single axis motion. - When the specified axis group is disabled, it will change its state from “Standby” to “Disabled”, and the designated axes in the group will change their state from “Coordinated” to “Standstill”. _3 Note: refer to 7.4 State Transitions of AH Motion Controller – Operation Manual for more information about state transitions. Inputs Outputs Outputs Update Timing 3-274 FB/FC Description FB DFB GroupDisable disables the axis group with the specidied group number.
_ Name Function Data type Setting value (Default value) Timing for updating GroupNum Specifies the number of the axis group. WORD 1~16 (0) When Execute shifts to True and Busy is False. Execute Writes in the parameters when Execute changes to True. BOOL True/False (False) - Name Function Data type Output range (Default value) Done True when the axis group is disabled. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions.
DWORD 16#0~16#FFFFFFFF (0) Name Timing for shifting to True Timing for shifting to False Done When the parameter setting is completed. When Execute shifts from True to False. If Execute is False and Done shifts to True, it will be True for only one period and immediately shift to False.