AH Motion Controller – Motion Control Instructions Manual DFB_HCnt - You can specify the high speed counter to be enabled by Channel , the input pulse type by InputType , the initial value _3 of the counter by InitiaValue , and trigger the corresponding X signal to clear the count value by setting ExtRstEN as True . - To read the count value during the high speed counter operation, you can monitor the output CountValue . Inputs 3-282 FB/FC Description FB DFB HCnt enables the specified high speed counter according to the specified parameters and monitors _ the count value.
Name Function Data type Setting value Timing for updating (Default value) Channel Specifies the counting channel of the high speed counter. eDFB H _ CNT*1 200: DFB AC0 _ 204: DFB AC4 _ 208: DFB AC8 _ 212: DFB AC12 _ 216: DFB AC16 _ 220: DFB AC20 (0)*_2 When Enable shifts to True Enable Enables the specified high speed counter when Enable changes to True. BOOL True/False(False) - ExtRstEN Resets the counter BOOL True/False(False) When Enable shifts to True InputType Input pulse type U/D: counting up/down P/D: pulse/direction A/B: A/B-phase 4A/B: quadruple A/B-phase eDFB H _ CNT INT _ YPE 0: UD 1: PD 2: AB 3:
AB4 (0) When Enable shifts to True InitiaValue Initial value of the specified counter DWORD Negative integer, positive integer or 0 (0) When Enable shifts to True