Chapter 3 Motion Control Instructions * Note: 2. The setting values, devices, corresponding terminals for Channel inputs: 1. Refer to Section 2.4 Data Type Unit (DUT): ENUM for explanation on using enumerations. 3. For resetting the counter value, refer to the selected DFB_Hcnt Channel and its corresponding terminals.
3_ Outputs Outputs Update Timing 3-283 Channel Setting value Device Corresponding terminals for counting 0 200 AC00 X0.8, X0.9 1 204 AC04 X0.10, X0.11 2 208 AC08 X0.12, X0.13 3 212 AC12 X0.14, X0.15 4 216 AC16 X1.0, X1.1 5 220 AC20 X1.2, X1.3 Channel Corresponding terminals for resetting 0 X0.0 1 X0.1 2 X0.2 3 X0.3 4 X1.4 5 X1.5 Name Function Data type Output range (Default value) Valid True when the output value is valid. BOOL True/False (False) Busy True when the instruction is enabled. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions.
DWORD 16#0~16#FFFFFFFF (0) CountValue Count value of the counter DWORD Continuously updates value when Valid is True. Name Timing for shifting to True Timing for shifting to False Valid When the output value is valid; one scan cycle after Enable shifts to True. When Enable shifts to False. When Error shifts to True. Busy When Enable shifts to True. When Enable shifts to False. When Error shifts to True.