Delta Electronics AH — DFB_Compare

AH Motion Controller – Motion Control Instructions Manual DFB_Compare _3 - You can specify the high speed comparator to be enabled by Channel , designate the comparison source by Source , and set the parameters for comparison by CmpMode and CmpValue. - When the comparison result is True, DFB_Compare will outputs the results according to the settings of OutputDevice and OutputMode.  Inputs 3-288 FB/FC Description FB DFB Compare compares the designated source value and the setting value and then to Set or Reset the _ desired device when the comparison result is True or False.

Name Function Data type Setting value Timing for (Default value) updating Channel Specifies the number of the high speed comparator. eDFB CO _ MP 0: Ch0 1: Ch1 2: Ch2 3: Ch3 4: Ch4 5: Ch5 6: Ch6 7: Ch7 8: Ch8 9: Ch9 10: Ch10 11: Ch11 12: Ch12 13: Ch13 14: Ch14 15: Ch15 (0) When Enable shifts to True Enable Enables the specified high speed comparator when Enable changes to True. BOOL True/False(False) -