Delta Electronics AH — DFB_Capture2

Chapter 3 Motion Control Instructions InitialValue = 0 MaskValue = 500 CapLen = 1000 CapLenMax = 1300 Enable Trigger CapFlag CapLenBe yondFlag 3_ Position -1000 0 1000 2000 3000 4000 5000 6000 -2000 1900 1600 1100 CapValue= 900 CapValue= 3000 CapValue= 1900  FirstMark FirstMark selects the reference of the mask range. 1. FirstMark =False When the instruction is enabled with the condition FirstMark =False, the instruction will use the initial value ( InitialValue ) as the reference center for the mask range when the first Capture occurs. Refer to below diagram: a. When InitialValue =600, the initial captured value will be 600 when the instruction is enabled.

In this case, 600 will also be the reference center for the mask range when the first Capture occurs. b. Because FirstMark =False, the mask range will be 100~1100. In the diagram the 1 st Capture occurs within the mask range, so the captured value will remain the initial value 600. 3-301 500 500