AH Motion Controller – Motion Control Instructions Manual InitialValue = 500 MaskValue = 500 Enable Trigger FirstMark CapFlag 4000 -2000 Position -1000 _3 2. FirstMark =True CapValue= 500 When the instruction is enabled with the condition FirstMark =True, the instruction will use the first captured value as the reference center for the mask range when the first Capture occurs. Refer to below diagram: a. When InitialValue =600, the initial captured value will be 600 when the instruction is enabled b. Because FirstMark =True, the instruction will use the first captured value as the reference center for the mask range. The mask function will be invalid until the first capture occurs.
In the diagram the 1 st Capture occurs at 1000, so the captured value changes from 600 to 1000, which is also the reference center of the mask range. The mask range will be 500~1500. c. The 2 nd Capture occurs withn the mask range 500~1500, so the captured value remains 1000. d. The 3 rd Capture occurs at 3000, which is out of the mask range 500~1500, so the captured value changes to 3000. InitialValue = 500 MaskValue = 500 Enable Trigger FirstMark CapFlag Position -1000 4000 -2000 CapValue= 1000 CapValue= 1000 CapValue= 3000 3-302 1st 500 500 1000 2000 3000 500 500 50 1 500 1st 2nd rd 3 500 500 500 0 500 1000 2000 30 500 00 500 500