Delta Electronics AH — DFB_ECATServoWrite

Chapter 3 Motion Control Instructions DFB_ECATServoWrite  Inputs 3_ 3-311 FB/FC Description FB DFB ECATServoWrite writes the values of parameters into the Delta servo drive specified on an _ EtherCAT network. Name Function Data type Setting value Timing for updating (Default value) Execute Executes the instruction when Execute changes to True. The value of the specified parameter will then be written into the servo drive. BOOL True/False (False) - Group Group number (Please refer to the user manual of the applied Delta servo drive for more information.) WORD 0~9 (0) When Execute shifts to True and Busy is False.

Parameter Parameter number (Please refer to the user manual of the applied Delta servo drive for more information.) WORD 0~99 (0) When Execute shifts to True and Busy is False. Value Value of a parameter (Please refer to the user manual of the applied Delta servo drive for more information.) DWORD 16#0~16#FFFFFFF F (0) When Execute shifts to True and Busy is False. DataType Data length WORD 0: mc16bits: 0 1: mc32bits: 1 When Execute shifts to True and Busy is False. Retry Number of times for auto-retry when an error occured on reading the parameter values. WORD 0~65535 (0) When Execute shifts to True and Busy is False.