AH Motion Controller – Motion Control Instructions Manual Outputs Outputs Update Timing _3 Timing Diagram Troubleshooting - If an error occurs during the execution of the instruction or when the axis is in the state of Errorstop, Error will change to True and the axis will stop moving. You can refer to ErrorID (Error Code) to address the problem. - Information regarding error codes and indicators and the associated troubleshooting information are attached as Appendices for a quick reference. For the complete troubleshooting of the system, refer to AH Motion Controller – Operation Manual .
3-312 Name Function Data type Output range (Default value) Done True when the specified data is read. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions. WORD 16#0~16#FFFFFFFF (0) Name Timing for changing to True Timing for changing to False Done When the value of the specified parameter is written. When Execute shifts from True to False. If Execute is False and Done shifts to True, Done will be True for only one period and immediately shift to False. Busy When Execute changes to True.
When Done shifts to True. When Error shifts to True. Error/ErrorID When an error occurs in the execution conditions or input values for the instruction. (error code is recorded) When Execute shifts from True to False. (error code is cleared)