AH Motion Controller – Motion control Instructions Manual _A2 A-72 Error Code Description Corrective action 16#3431 Motion axis number is used repeatly in the same group. Cause: DFB GroupEnable, one of the AxisNumorder1~ _ AxisNumorder6 is used repeatly in the same group. Action: set up the AxisNumorder again and re-execute the function block 16#3432 The specified group number does not exist. Cause: The specified group number does not exist. Action: set up an valid group name and enable it. 16#3433 The number of axes is insufficient for the specified group axes motion. Cause: The number of axes is insufficient for the specified group axes motion. Action:

set up the group name of the function block, the axis number should be as many as required, for example, a liner interpolation motion requires 2 axes while an arc interpolation motion requires 3 axes to complete the task. 16#3434 DFB GroupDisable is executed _ when group motion is in progress. Cause: DFB GroupDisable is executed when group motion is _ in progress. Action: use DFB GroupReset to clear this error. _ 16#3435 The same motion axis number is used repeatly in the different groups. Cause: DFB GroupEnable, one of the AxisNumorder1~ _ AxisNumorder6 is used repeatly in the different groups. Action: set up the AxisNumorder again and re-execute the function block.

16#3436 The axis number of the first order should be a positive number or a number other than 0. Cause: AxisNumorder1 is a negative number or zero in DFB GroupEnable. _ Action: set up the value of AxisNumorder1 again and re-execute the function block. 16#3437 The group number exceeds the setting range. Cause: the value in GroupNum is not in the range of 1~16. Action: set up the value of GroupNum again and re-execute the function block. 16#3438 The designated group is in “ErrorStop” state. Cause: the designated group is in “ErrorStop” state. Action: use DFB GroupReset to clear the error _ 16#343A Group is executing the function block ImmediateStop. Cause:

group is executing the function block ImmediateStop. Action: use DFB GroupReset to clear the error _ 16#3463 The designated ECAT Slave does not exist. Cause: the designated ECAT Slave does not exist. Action: make sure the designated ECAT Slave can perform axis operation. 16#3501 The selected channel has been used in FB. Cause: the channel to be set has already been used Action: select a channel that is not used or free the used channel for setup 16#3505 An error occurs when writing CAM data. Cause: read the CAM data but to find the data is not as it is written. Action: re-execute the CAM function block to write 16#3512 CAM data does not exist. Cause: CAM data does not exist. Action:

make sure the CAM data is correct and download the CAM data again.