Appendix 6. Data Type Unit: Enum A2_ A-75 Error Code Description Corrective action 16#7002 This function is not available for CPU modules. Check the CPU firmware version. 16#7203 Invalid access code Check the content of the packet sent by the device to be connected. 16#7401 Function code error Check the content of the packet sent by the device to be connected. 16#7402 The packet exceeds the max. data length. Check the content of the packet sent by the device to be connected. 16#7407 Non-ASCII characters exist in the command. Check the content of the packet sent by the device to be connected.
16#7408 PLC is in RUN mode Data download for program or CPU parameters is not allowed when PLC is in RUN mode. 16#740A The CPU memory is being written or failed to be written. Flash/SD card is being written. Please try again later. 16#740B The Clear or Reset operation is in progress. The RST/CLR operation is in progress. Please try again later. 16#740C The backplane number in a communication command is incorrect. Please check the PLC firmware and the software version and contact the supplier. 16#740D The slot number in a communication command is incorrect. Please check the PLC firmware and the software version and contact the supplier.
16#740E Error occurs when clearing the memory Please try again. If the error occurs again, contact the supplier. 16#740F Communication timeout Check if the device to be connected is in normal operation. 16#7410 The received Function Code doesn’t match the current Function Code. Check the packet content sent by the remote device. 16#7412 Data cannot be downloaded to CPU because SW1 is ON. Confirm that SW1 is OFF. 16#757D The number of times users can enter the PLC password is 0. The password retry limit is reached. Please power on the PLC again. 16#757E Incorrect PLC password Check if the password is correct.