AH Motion Controller – Motion Control Instructions Manual MC_Power Inputs _3 *Note : 1. Motion control instructions can control the axis to perform the corresponding motion only after Enable of MC_Power changes to True. 2. Refer to Section 2.4 Data Type Unit (DUT): ENUM for explanation on using enumerations. Outputs 3-12 FB/FC Description FB MC Power enables or disables the corresponding servo axis. _ Name Function Data type Setting value Timing for updating (Default value) Enable The axis is ready to be operated when Enable is True, and not ready when Enable is False. BOOL True/False (False) - EnablePositive Enables motion in positive direction when EnablePositive is True.
Valid only when Enable is True. BOOL True/False (False) Continuously updates value when Enable is True. EnableNegative Enables motion in negative direction when EnableNegative is True. Valid only when Enable is True. BOOL True/False (False) Continuously updates value when Enable is True. Mode Specifies the buffering behavior of the instruction when Enable changes to False. eMC SERV _ OOFF MOD _ E*2 0: mcAborting 1: mcBuffered (0) When Enable shifts to False Name Function Data type Output range (Default value) Status True when the axis is ready to be operated. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False)