Chapter 3 Motion Control Instructions  Outputs Update Timing 3_ *Note : Busy and Active will not shift to False when Enable is reset. The two outputs will be reset only when an error occurs.  Timing Diagram  In-Outs *Note : Kn refers to the maximum supported axes of different models. For example, AH20EMC-5A supports K1~K32. 3-13 Name Function Data type Output range (Default value) Active True when the axis is being controlled. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs.

Refer to Appendices for error code descriptions DWORD 16#0~16#FFFFFFFF (0) Name Timing for shifting to True Timing for shifting to False Status  When Enable shifts to True and the axis is ready to be operated.  When Enable shifts to False.  When Error shifts to True. Busy*  When the function block instance is enabled (En= True) and no error exists.  When Error shifts to True. Active*  When the function block instance is enabled (En= True) and no error exists.  When Error shifts to True. Error/ErrorID  When an error occurs in the execution conditions or input values for the instruction.(Error code is recorded)  When the error is cleared.

Name Function Data type Setting value Timing for updating (Default value) Axis Motion axis number WORD K1~Kn* (0) When Enable shifts to True and Busy is False.