Chapter 3 Motion Control Instructions Troubleshooting - If an error occurs during the execution of the instruction or when the axis is in the state of “Errorstop”, Error will change to True and the axis will stop moving. You can refer to ErrorID (Error Code) to address the problem. - Information regarding error codes and indicators are attached as Appendices for a quick reference. The detailed troubleshooting procedures are explained in AH Motion Controller – Operation Manual . 3_ Programming Example 1 The example below describes the behavior of the EnablePositive of MC_Power in combination with MC_MoveVelocity. direction.
In this case, there will be an error if the instruction for moving the axis forward is executed. When the axis moves When Enable is True and EnablePositive is False, motion instructions are not allowed to move the specified in positive in positive direction and EnablePositive changes from True to False, the axis will decelerate its speed at the decelerate rate specified by the current motion instruction and stop at the velocity 0. 3-15 Input Mode Description Mode 0: mcAborting When Enable changes to False, the axis will enter the “Disabled” state immediately, and the motion controller will stop the slave axis from moving (within one sync cycle).
Be cautious during operation in case of any danger! 1: mcBuffered When Enable changes to False, the axis will enter the “Disabled” state only after it changes to the “Standstill” state. The axis will complete its motion before entering “Standstill” state.