AH Motion Controller – Motion Control Instructions Manual Motion diagram: _3 - When M2( Execute ) changes to True for the first time, the servo motor cannot move and M24( Error ) changes to True. The servo motor is forbidden to move forward at the moment because M5( EnablePostive ) is False. When M2( Execute ) changes to True for the second time with M5( EnablePostive )=True , the motion controller starts to move the servo motor forward. When the servo motor reaches the target velocity, M20( InVelocity ) will change to True. - When M5( EnablePostive ) changes to False, the MC_MoveVelocity instruction is aborted and M23( CommandAborted ) changes to True.
Meanwhile the servo motor begins to decelerate its speed at the deceleration rate specified by the MC_MoveVelocity instruction. - When M2( Execute ) changes to False, M23( CommandAborted ) changes to False. - When M1( Enable ) changes to False, M10 ( Status ) changes to False. 3-16 Velocity 300 Time MC Power _ M1(Enable) M5(EnablePostive) M10(Status) M11(Busy) M12(Active) MC MoveVelocity _ M2(Execute) M20(InVelocity) M21(Busy) M22(Active) M23(CommandAborted) M24(Error) MC MoveVelocity _ M2(Execute) M20(InVelocity) M21(Busy) M22(Active) M23(CommandAborted) M24(Error)