Delta Electronics AH — MC_Home

AH Motion Controller – Motion Control Instructions Manual MC_Home - Position is used to specify the absolute home position after homing is completed. _3 - The instruction will complete in “Standstill” state if it was executed in “Standstill” state.  Inputs *Note: 1. Refer to Section 2.4 Data Type Unit (DUT): ENUM for explanation on using enumerations. 3-24 FB/FC Description FB MC Home drives the axis to perform the homing operation. _ Name Function Data type Setting value (Default value) Timing for updating Execute Executes the instruction when BOOL True/False - Execute changes to True. (False) Position Sets the home absolute home position after homing is completed. (Unit:

user unit)*1 LREAL Negative number, positive number or 0 (0) When Execute shifts to True and Busy is False HomeMode Specifies the axis behavior of the homing process. WORD 0-35 (0) When Execute shifts to True and Busy is False BufferMode Reserved eMC BUFF _ ER MODE _ When Execute shifts to True and Busy is False.