Chapter 3 Motion Control Instructions Outputs Outputs Update Timing 3_ 3-25 Name Function Data type Output range (Default value) Done True when homing is completed. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Active True when the axis is being controlled. BOOL True/False (False) CommandAborted True when the instruction is aborted. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions. DWORD 16#0~16#FFFFFFFF (0) Name Timing for shifting to True Timing for shifting to False Done When the homing is completed.
When Execute shifts from True to False. If Execute is False and Done shifts to True, Done will be True for only one period and immediately shift to False. Busy When Execute changes to True. When Done shifts to True. When Error shifts to True. When CommandAborted shifts to True. Active When the motion on the axis is started. When Done shifts to False. When an error occurs When CommandAborted shifts to True. If Execute is False and Active shifts to True, it will be True for only one period and immediately shift to False. CommandAborted When this instruction is aborted by another instruction. When Execute changes to False.
If Execute is False and CommandAborted shifts to True, it will be True for only one period and immediately shift to False. Error/ErrorID When an error occurs in the execution conditions or input values for the instruction.(Error code is recorded) When Execute shifts from True to False. (Error code is cleared)