Delta Electronics AH — MC_Home

AH Motion Controller – Motion Control Instructions Manual  Timing Diagram _3  In-Outs *Note : Kn refers to the maximum supported axes of different models. For example, AH20EMC-5A supports K1~K32.  Function - When Execute changes to True, the homing operation starts to be performed on the axis specified in Axis. - The parameters used in MC_Home can be set in the axis’ parameters. - There are 36 homing methods supported by Delta motion controllers and Delta servo drives. You can specify the desired homing mode in the instruction. - When working with the instruction MC_STOP and set the deceleration to 0, users need to check the definition of OD 6085 hex on the corresponding slave.

 Software Limit  When the axis runs beyond the software limit set, an error will be reported.  When the axis is in the homing mode, software limit will not be taken into account. (Even if the axis runs beyond the software limt set, no error will be reported.)  Homing Modes homing modes are manufacturer dependent. For the supported homing modes of products other than Delta drives, Delta servo drives, e.g. ASDA A2-E, supports up to 35 homing modes which are defined in CiA 402*. The supported refer to the information provided by the servo drive manufacturer. Note:

CiA stands for CAN in Automation, which is the nonprofit organization that supports standardization of CAN protocols and develops and publishes CiA specifications . 3-26 Name Function Data type Setting value Timing for updating (Default value) Axis Motion axis number WORD K1~Kn* (0) When Execute is rising edge triggered and Busy is False.