Delta Electronics AH — MC_Home

Chapter 3 Motion Control Instructions 3_ 3-27 Homing Description Delta servo drive modes (ASDA-A2-E) 0 Reserved None 1 Homing on the negative limit switch and index pulse OK 2 Homing on the positive limit switch and index pulse OK 3 Homing on the positive home switch and index pulse OK 4 Homing on the positive home switch and index pulse OK 5 Homing on the negative home switch and index pulse OK 6 Homing on the negative home switch and index pulse OK 7 Homing on the home switch and index pulse OK 8 Homing on the home switch and index pulse OK 9 Homing on the home switch and index pulse OK 10 Homing on the home switch and index pulse OK 11 Homing on the home switch and index pulse OK 12 Homing on the home switch and index pulse OK 13 Homing on the home switch and index pulse OK 14 Homing on the home switch and index pulse OK 15 Reserved None 16 Reserved None 17 Like 1 but Homing without an index pulse OK 18 Like 2 but Homing without an index pulse OK 19 Like 3 but Homing without an index pulse OK 20 Like 4 but Homing without an index pulse OK 21 Like 5 but Homing without an index pulse OK 22 Like 6 but Homing without an index pulse OK 23 Like 7 but Homing without an index pulse OK 24 Like 8 but Homing without an index pulse OK 25 Like 9 but Homing without an index pulse OK 26 Like 10 but Homing without an index pulse OK 27 Like 11 but Homing without an index pulse OK 28 Like 12 but Homing without an index pulse OK