AH Motion Controller – Motion Control Instructions Manual MC_Stop - MC_Stop stops a moving axis according to the specified mode and transfers the axis to the state of “Standstill”. _3 - It aborts any executing instruction. No other instructions can be executed while the axis is in the state of “Stopping”. - When 0 velocity is reached, Done will be True immediately and the state of “Stopping” remains. - The axis enters the state of “Standstill” when Done changes to True and Execute changes to False. Inputs *Note: Set the deceleration to 0, while executing MC_Stop; the system will go to Immediate Stop or Deceleration Stop mode according to the parameters set in ISPSoft.
(When working with the instruction MC_Home and set the deceleration to 0, users need to check the definition of OD 6085 hex on the corresponding slave.) Refer to Section 2.2.1 Parameters for Motion Axes: Structure for explanation on setting axis parameters. Outputs 3-32 FB/FC Description FB MC Stop decelerates an axis to a stop. _ Name Function Data type Setting value (Default value) Timing for updating Execute Executes the instruction when Execute changes to True. BOOL True/False (False) - Deceleration Deceleration rate (Unit: user unit/s2)* LREAL Positive number or 0 (0) When Execute is rising edge triggerred and Busy is False. Jerk Jerk value (Unit:
user unit/s3)* LREAL Positive number or 0 (0) When Execute is rising edge and Busy is False. Name Function Data type Output range (Default value) Done True when zero velocity is reached. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Active True when the axis is being controlled. After a complete stop Active remains True until the axis is released with Execute=False. BOOL True/False (False) CommandAborted True when the instruction is aborted. BOOL True/False (False)