Chapter 3 Motion Control Instructions Outputs Update Timing 3_ 3-33 Name Function Data type Output range (Default value) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions. DWORD 16#0~16#FFFFFFFF (0) Name Timing for shifting to True Timing for shifting to False Done True when the axis decelerates to a stop and reaches zero velocity. When Execute shifts from True to False. If Execute is False and Done shifts to True, it will be True for only one period and immediately shift to False. Busy True when Execute shifts to True and the instruction is executed.
When Done shifts to True. When Error shifts to True. When CommandAborted shifts to True. Active True when this instruction is started. When Execute shifts to False and Done is True. When Done shifts to True and Execute is False. When Error shifts to True. When CommandAborted shifts to True. If Execute is False and Active shifts to True, it will be True for only one period and immediately shift to False. CommandAborted When this instruction is aborted because another motion control instruction is executed. When Execute shifts from True to False. If Execute is False and CommandAborted shifts to True, it will be True for only one period and immediately shift to False.
Error/ErrorID When an error occurs in the execution conditions or input values for the instruction.(Error code is recorded) When Execute shifts from True to False. (Error code is cleared)