Delta Electronics AH — MC_Stop

AH Motion Controller – Motion Control Instructions Manual  Timing Diagram _3  In-Outs *Note : Kn refers to the maximum supported axes of different models. For example, AH20EMC-5A supports K1~K32.  Function You can set the inputs Deceleration and Jerk to specify the deceleration rate and jerk pattern when decelerating to a stop. - The relationship between the deceleration rate, the velocity, and the jerk values is shown below Jerk=0 The velocity value is created according to the specified deceleration rate Dt Velocity Vt Velocity Time O Deceler- ation speed -Dt Time Time Jerk=0 Vt: Velocity before the deceleration starts, Dt:

The specified deceleration speed 3-34 Name Function Data type Setting value Timing for updating (Default value) Axis Motion axis number WORD K1~Kn* (0) When Execute is rising edge triggered and Busy is False. Command current position