Delta Electronics AH — MC_Stop

Chapter 3 Motion Control Instructions Jerk≠0 deceleration speed. The velocity value is created according to the specified deceleration rate Dt, which functions as the upper limit to the Velocity Vt Velocity Command current position Time O Deceler- ation speed -Dt Time Jt Time Jerk value -Jt Vt: Velocity before the deceleration slope starts, Dt: The specified deceleration rate, Jt: The specified jerk value 3_  Troubleshooting - If an error occurs during the execution of the instruction or when the axis is in the state of Errorstop, Error will change to True and the axis will stop moving. You can refer to ErrorID (Error Code) to address the problem.

- Information regarding error codes and indicators are attached as Appendices for a quick reference. The detailed troubleshooting procedures are explained in AH Motion Controller – Operation Manual .  Programming Example The example below shows the behavior when MC_Stop is used with MC_MoveVelocity. A moving axis is delcelerating with MC_Stop instruction. executed, when MC_Stop is busy, it will report CommandAborted. The axis rejects motion instructions when Execute of MC_Stop is True. If any motion instruction (ex. MC_MoveVelocity) is 3-35