Delta Electronics AH — MC_Stop

Chapter 3 Motion Control Instructions Motion diagram: 3_ - When M3( Execute ) of MC_Stop changes to True, it triggers M23( CommandAboted ) of MC_MoveVelocity at the same time and the motion controller starts to decelerate the axis to a stop. The Axis state is moved to the “Stopping”. - When the axis reaches zero velocity, M30( Done ) will change to True. M3( Execute ) is still True so the axis state remains in the state “Stopping”. - If MC_MoveVelocity is executed again while the axis state is “Stopping”, the execution of - As soon as M30( Done ) is set ON and M3( Execute ) is False, the axis state goes to “Standstill”.

MC_MoveVelocity will be aborted and CommandAborted will be reported (M23=True)  Supported Products − AH Motion Controller CPU: AHxxEMC-5A − AH series motion control modules: AHxxEMC-5A 3-37