AH Motion Controller – Motion Control Instructions Manual MC_Halt - MC_Halt stops a moving axis which is under normal operation and tansfers the axis to the state “DiscreteMotion” until _3 zero velocity is reached. When the axis stopped, Done changes to True and the axis enters the state “Standstill”. - It is possible to execute another motion instruction during deceleration of the axis if it is not in a buffer mode. The executed motion instruction will abort MC_Halt and operate immediately. - During the execution of MC_Halt, it is invalid to execute this instruction repeatedly. Inputs *Note: 1. Refer to Section 2.4 Data Type Unit (DUT): ENUM for explanation on using enumerations.
3-38 FB/FC Description FB MC Halt halts an axis. _ Name Function Data type Setting value (Default value) Timing for updating Execute Executes the instruction when Execute changes to True. BOOL True/False (False) - Deceleration Deceleration rate. (Unit: user unit/s2) *1 LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. Jerk Jerk value. (Unit: user unit/s3) *1 LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. BufferMode Specifies the buffering behavior of the instruction. eMC BUFFER _ MODE*2 _ 0: mcAborting 1: mcBuffered (0) When Execute shifts to True and Busy is False.