Delta Electronics AH — MC_Halt

Chapter 3 Motion Control Instructions  Outputs  Outputs Update Timing 3_ 3-39 Name Function Data type Output range (Default value) Done True when zero velocity is reached. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Active True when the axis is being controlled. BOOL True/False (False) CommandAborted True when the instruction is aborted. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions.

DWORD 16#0~16#FFFFFFFF (0) Name Timing for shifting to True Timing for shifting to False Done  When the axis decelerates to a stop and reaches zero velocity.  When Execute shifts from True to False.  If Execute is False and Done shifts to True, it will be True for only one period and immediately shift to False. Busy  When Execute shifts to True and the instruction is executed.  When Done shifts to True.  When Error shifts to True.  When CommandAborted shifts to True. Active  When this instruction is started.  When Done shifts to True.  When Error shifts to True.  When CommandAborted shifts to True.

 If Execute is False and Active shifts to True, it will be True for only one period and immediately shift to False. CommandAborted  When this instruction is aborted because another motion control instruction is executed.  When Execute shifts from True to False.  If Execute is False and CommandAborted shifts to True, it will be True for only one period and immediately shift to False. Error/ErrorID  When an error occurs in the execution conditions or input values for the instruction.(Error code is recorded)  When Execute shifts from True to False. (Error code is cleared)