Delta Electronics AH — 5.2.12. Timers (T)

AH Motion Controller – Operation Manual 9. When the instruction TMR is executed, the specified timer coil is ON and the timer begins to count. As the value of the timer matches the setting value, the state of the contact is as follows.  General-purpose timer the setting value, the output coil is ON. When the instruction TMR is executed, the general-purpose timer begins to count. As the value of the timer matches 10 sec X0.0 SV: K100 T0 (PV) Y0.0 _5  Accumulative timer When the instruction TMR is executed, the accumulative timer begins to count. As the value of the timer matches the setting value, the output coil is ON.

As long as users add the letter S in front of the letter T, the timer becomes the accumulative timer. When the conditional contact is OFF, the value of the accumulative timer is not reset. When the conditional contact is ON, the timer will count from the current value. 5-8 Normally open (NO) contact ON Normally closed (NC) contact OFF