Chapter 9 Troubleshooting 9_ 9-71 Error code Description Corrective action 16#A011 The setting of the JOG speed is incorrect. The setting value can not be zero. 16#A012 The positive pulses generated by the single-axis clockwise motion are inhibited. The error occurs because the limit sensor is triggered. Check the status of the limit sensor, and check whether the motor operates normally. 16#A013 The negative pulses generated by the single-axis counterclockwise motion are inhibited. The error occurs because the limit sensor is triggered. Check the status of the limit sensor, and check whether the motor operates normally. 16#A014 The limit switch is reached.
The error occurs because the limit sensor is triggered. Check the status of the limit sensor, and check whether the motor operates normally. 16#A015 The device which is used exceeds the device range. Use the device which does not exceed the device range. 16#A017 An error occurs when the device is modified by a 16-bit index register/32-bit index register. Use the16-bit index register/32-bit index register which does not exceed the device range. 16#A018 The conversion into the floating-point number is incorrect. Modify the operation to prevent the abnormal number from occurring. 16#A019 The conversion into the binary-coded decimal number is incorrect.
Modify the operation to prevent the abnormal number from occurring. 16#A01A Incorrect division operation (The divisor is 0.) Modify the operation to prevent the divisor from being zero. 16#A01B General program error Modify the program to make the syntax correct. 16#A01C LD/LDI has been used more than nine times. Modify the program to prevent LD/LDI from being used more than nine times. 16#A01D There is more than one level of nested program structure supported by RPT/RPE. Modify the program to prevent more than one level of nested program structure supported by RPT/RPE from being used. 16#A01E SRET is used between RPT and RPE.
Modify the program to prevent SRET from being used between RPT and RPE. 16#A01F There is no M102 in the main program, or there is no M2 in the motion program. Modify the program so that there is M102 in the main program, or modify the program so that there is M2 in the motion program. 16#A020 The wrong instruction is used, or the device used exceeds the range. Check and modify the program to prevent the wrong instruction from being used, or check whether the device used exceeds the device range.