AH Motion Controller - Operation Manual I/O Refreshing and Communication Service I/O refreshing _A1 A CPU module reads external I/O data periodically or output data to external I/O. I/O refreshing includes the following. Refreshing data in a digital I/O module Refreshing data in an analog I/O module Refreshing data in a network module Refreshing data in a motion control module All I/O refreshing is executed in the same loop. The data in an input device is refreshed before a program is executed, and the data in an output device is refreshed after the program is executed. Communication service Communication service is nonscheduled communication service of a network module.
It includes the communication request sent from external equipment to a CPU module, and the communication request sent from the CPU module to the external equipment. A-8 Unit Maximum data exchange Data exchange area Digital I/O module It depends on the number of input/output channels in the unit. Input relay/Output relay Analog I/O module It depends on the number of input/output channels in the unit. Data register Network module It depends on the unit. Data register Motion control module It depends on the unit. Data register