Chapter 5 Applied Instructions S : Source device; D : Device in which an operation result is stored Explanation EXP [ D +1, D ] =[ S +1 , S ] e is a base (e=2.71828), and S is an exponent. The value in S can be a positive value or a negative value. D must be a 32-bit register, and the value in S must be a floating-point value. The value in D is e S . (e is 2.71828, and S represents a source value.) If the absolute value of an oepration result is greater than the maximum floating-point value available, a carry flag will be ON. If the absolute value of an oepration reuslt is less than the minimum floating-point value available, a borrow flag will be ON.
If an operation result is 0, a zero flag will be ON. SM1064 is the zero flag in an Ox motion subroutine, and SM968 is the zero flag in O100. SM1065 is the borrow flag in an Ox motion subroutine, and SM969 is the borrow flag in O100. SM1066 is the carry flag in an Ox motion subroutine, and SM970 is the carry flag in O100. When M0 is ON, the value in (D1, D0) is converted into a floating-point value, and the conversion result is stored in (D11, D10). When M1 is ON, the exponentiation with the value in (D11, D10) as an exponent is performed. The result is a floating-point number, and is stored in (D21, D20).
Example Additional remark Please refer to section 5.3 for more information about performing operations on floating-point numbers. 5-87 API Instruction code Operand Function Exponent of a binary 124 D EXP P S, D floating-point number Device Xn.n Yn.n M S K 16# F KnM KnS D W T C V Z S D Pulse instruction 16-bit instruction 32-bit instruction (6 steps) – M0 DFLT D0 D10 M1 DEXP D10 D20 DFLT D0 D10 DEXP D10 D20