Mitsubishi — 5.6 Descriptions of the Applied Instructions

Chapter 5 Applied Instructions  S 1 : Device in which a base is stored; S 2 : Device in which a power is stored; D : Device in which the operation result is stored  The binary floating-point value in S 1 is raised to the power of the value in S 2 , and the operation result is stored in D . D =POW[ S 1 +1, S 1 ] [ S2 +1, S2 ]  The value in S 1 can only be a positive value, whereas the value in S 2 can be a positive value or a negative value. D must be a 32-bit register, and the values in S 1 and S 2 must be floating-point values.

 If the values in S 1 and S 2 are invalid, an operation error will occur, the instruciton will not be executed, an operation error flag will be ON, and the error code 16#0E19 will appear.  If the absolute value of an operation result is greater than the maximum floating-point value available, a carry flag will be ON.  If the absolute value of an operation reuslt is less than the minimum floating-point value available, a borrow flag will be ON.  If an operation result is 0, a zero flag will be ON.  SM1064 is the zero flag in an Ox motion subroutine, and SM968 is the zero flag in O100.  SM1065 is the borrow flag in an Ox motion subroutine, and SM969 is the borrow flag in O100.

 SM1066 is the carry flag in an Ox motion subroutine, and SM970 is the carry flag in O100.  SM1049 is the operation error flag in an Ox motion subroutine, and SM953 is the operation error flag in O100. Explanation Example  When M0 is ON, the values in (D1, D0) and (D3, D2) are converted into binary floating-point values, and the conversion results are stored in (D11, D10) and (D13, D12) respectively.  When M1 is ON, the binary floating-point value in (D11, D10) is raised to the power of the binary floating-point value in (D13, D12), and the operation result is stored in (D21, D20).

M0 DFLT DFLT M1  Please refer to section 5.3 for more information about performing operations on floating-point numbers. Additional remark 5-91 API Instruction code Operand Function S , S , D 1 2 Power of a 128 D POW P floating-point number Device Xn.n Yn.n M S K 16# F KnM KnS D W T C V Z S 1    S 2    D   Pulse instruction 16-bit instruction 32-bit instruction (9 steps)  –  D0 D10 D2 D12 DPOW D10 D12 D20