Mitsubishi — 5.10.1 Absolute Single-speed Motion

AH500 Motion Control Module Manual 4. Example Purposes:  After the first single-speed motion is complete, the second single-speed motion will be executed.  The second single-speed motion is executed before the execution of the first single-speed motion is complete. The motion control function block named FIRST is set so that the first axis moves at a speed of 2,000 pulses per second, and moves for 10,000 pulses. The motion control function block named SECOND is set so that the first axis moves at a speed of 3,000 pulses per second, and moves for 15,000 pulses.  After the first single-speed motion is complete, the second single-speed motion will be executed. Steps:

(a) Set Execute1 to True. (b) Wait for a transition in Done2’s signal from low to high or a transition in Error2’s signal from low to high.  The second single-speed motion is executed before the execution of the first single-speed motion is complete. Steps: (a) Set Execute1 to True. (b) Set Test to ON when Busy1 is set to True. (c) Wait for a transition in Done2’s signal from low to high or a transition in Error2’s signal from low to high. 5-140 Error Troubleshooting The motion control function block conflicts with other motion control function blocks.

Make sure that other uniaxial motion control function blocks are not started or the execution of other uniaxial motion control function blocks is complete before the motion control function block is started.